Pipe Coupling manufacturer, Coupling and Clamp Manufacturer, Grip Type, Multi Flex Type, Repair Hinge Type and more
LOW PRESSURE TEST PLUG (5-10Kg/㎠)
Purpose of Using the High Pressure Test Plug
The low pressure test plug is intended to check the pressure test at the end of the pipeline from 0 to 5 bar. There is no problem in repeated use and reduce costs and improve operational efficienciesis to the user in maintaining the pressure in the pipe.
HYDRO Test Plugs Reports for Steel Pipes
SIZE | Schedule | Low Pressure Test Plugs | ||
---|---|---|---|---|
Torque (N.m) | Working Pressure (kgf/㎠) | Bursting Pressure (Kgf/㎠) | ||
25A | #40 #80 | 30 25 | 2.0 2.0 | 6.0 6.0 |
32A | #40 #80 | 40 35 | 2.7 3.0 | 8.0 9.0 |
40A | #40 #80 | 50 45 | 2.0 2.3 | 6.0 7.0 |
50A | #40 #80 | 80 60 | 3.0 3.0 | 9.0 9.0 |
65A | #40 #80 | 140 120 | 2.0 2.0 | 6.0 6.0 |
80A | #40 #80 | 200 180 | 2.0 2.3 | 6.0 7.0 |
100A | #40 #80 | 240 220 | 1.5 1.5 | 4.5 4.5 |
125A | #40 #80 | 260 240 | 1.3 1.5 | 4.0 4.5 |
150A | #40 #80 | 280 280 | 1.2 1.2 | 3.5 3.5 |
HYDRO Test plugs Reports for CPVC
SIZE | Schedule | High Pressure Test Plugs | ||
---|---|---|---|---|
Torque (N.m) | Working Pressure (kgf/㎠) | Bursting Pressure (Kgf/㎠) | ||
32A | #80 | 50 | 17.5 | 70 |
40A | 60 | 17.5 | 70 | |
50A | 60 | 10.0 | 40 | |
65A | 70 | 7.5 | 30 | |
80A | 120 | 7.5 | 30 | |
100A | 150 | 7.5 | 30 |
SIZE | Schedule | High Pressure Test Plugs | ||
---|---|---|---|---|
Torque (N.m) | Working Pressure (kgf/㎠) | Bursting Pressure (Kgf/㎠) | ||
32A | #80 | 50 | 2.7 | 8.0 |
40A | 60 | 2.7 | 8.0 | |
50A | 60 | 2.7 | 8.0 | |
65A | 80 | 2.5 | 7.5 | |
80A | 100 | 2.5 | 7.5 | |
100A | 14 | 1.7 | 5.0 |