The doors on the ships or offshore facilities which sail or operate in the harsh weather area such as the Arctic, the Antarctic, the North Sea or Northern Sea Route must be operating at all times under any circumstances because it is directly related to the safety of crews.
E-TEC’s Door Heating system can be applied to all types of doors such as single doors, double doors, hydraulic doors and hatch doors.
Advantages
- Applicable to external weather tight doors
- Applicable to any doors with different types and sizes
Specification
Application | Door Heating | |
---|---|---|
Type of Cables | Self-Regulating Heating Cable | |
Supply Voltage | 208V ~ 277V (Standard : 230Vac) | |
Rated output based on temperature of the surroundings(w/m) | 10℃ | 47 |
-10℃ | - | |
-20℃ | - | |
-30℃ | - | |
-40℃ | - |
Image