English | Select | |
한국어 | Select | |
Русский | Select |
Electric Distribution Board
Our distribution board product adopts standardized parts and the introduction of our own smart manufacturing process to implement the efficiencies of material and personnel, saving the cost of manufacture. Based on our excellent experience and skill, the product can be customized to fit into various environments, at both land and sea.
SUMMARY
1.Electricity converted from extra-high voltage power is distributed through a protector
2.Load sensing and protection
3.Changes in capacity and additional load acceptable
4.Changes in dimension, specification etc. available depending on environmental conditions.
Specifications
RATED VOLTAGE | 600V AC (690 AC, option) | RATE FREQUENCY | 60Hz (50Hz, option) |
---|---|---|---|
RATED CURRENT | 8000 A Max | AMBIENT TEMPERATURE | -10 ~ 45¢®E ( 50¢®E,option) |
WITHSTAND CURRENT | 120KA, rms, sym, 1sec | RELATIVE HUMDIFY | 95% |
ENCLOSURE | Formed sheet steel, totally enclosed, dead-front, floor mounting type |
---|---|
PROTECTION DEGREE | IP 21, IP 22 (IP 23, option) |
POWER LINE INLET | Bottom or upper part of the rear (upper part, option). Connection to be done at the rear |
DOOR | Front-left hinged with door stopper Rear-Detachable type |
HANDRAIL | Front (rear, option) |
INSOLATION MATERIAL | Highly efficient insulation materials with sufficient mechanical strength against electromagnetic repulsive forces in case of short-circuits and against shock and/or vibration |
Technical Specifications
Generator panel
The generator panel has the major functions for switching, protection, indication, and monitoring of generator(s), and is usually located in the middle of the switchboard.
The panel is normally divided into two parts.
– Lower part : The withdrawable circuit breaker is installed and provides the functions of operating and breaking main power.
– Upper part : The measuring and indicating devices are mounted on the upper door and protection devices are mounted on the inner plate of pane
PANEL (Unit : mm)
GENERATOR CAPACITY | WIDTH | DEPTH | HEIGHT |
---|---|---|---|
up to 300KVA | 600(500) | 1000(700~1500) | 2100(1800~2300) |
301~1200KVA | 800(700) | ||
1201~1500KVA | 900(800) | ||
1501~2300KVA | 1000 | ||
2301~3000KVA | 1100 | ||
over 3000KVA | special design |
Remark:() is determined by the electrical design
Synchronizing panel
The synchronizing panel has the functions of power management and synchronizing the generator, for automatic operation of generator, additional synchronizing device can be provided on panel as option. The panel is normally divided into two parts. Dimension of panel
PANEL (Unit : mm)
NO. OF GENERATOR | WIDTH | DEPTH | HEIGHT |
---|---|---|---|
2 | 800(700) | 1000(700~1500) | 2100(1800~2300) |
3 | 800(700) | ||
4 | 1000 | ||
5 | 1000 | ||
2301~3000KVA | special design |
Feeder panel
The feeder panel has the function of power distribution to each load mainly with molded case circuit breakers. the width of panel can be sized from 700 to 1500mm depending on the current ratings and quantity of breakers. The depth and height are same as those of generator an synchronizing panels.
Automatic control device for generator (option)
The control device provides the automatic control and protective functions for generator.
The major functions are described as follows:
-Automatic power control
-Diesel engine control
-Generator status monitoring
-Protection and pane automation