English | Select | |
한국어 | Select | |
Русский | Select |
Model | BS-UTH |
---|---|
Used | To make the floor warm by radiant heat through electrical energy by installing heating cable under the floor |
Structure | ① Heating wire ② Insulation ③ Braid or spiral shield ④ Jacket |
The heating cable is installed under the floor of a building to use radiant heat by electric energy which makes the indoor environment more comfortable. These excellent double insulated tubes are made of silicones resistant to heat and electrical insulation, and fluoro-polymers resistant to wear. No damage can cause by insulation deterioration but strong mechanical strength that creates stable structure for snow/ice melting. This is a semi-permanent heating system that made up of non-magnetic heating cable which is a harmless to the human body by using blocked screen.
Technical Spec.
㎡ | LENGTH (M) | RESISTANCE (Ω) | HEATING CAPACITY (W/H) | TECHNICAL SPECIFICATION |
---|---|---|---|---|
1.65 | 14 | 172.8 | 280 | 1. Voltage : 100-220V, Max. 380V 2. Power : 280-2240W 3.Temp. in use : 105℃ 4.Heating Temp. on Floor : 5℃ to 60℃ |
3.3 | 28 | 86.4 | 560 | |
6.6 | 56 | 43.2 | 1120 | |
9.9 | 84 | 28.8 | 1680 | |
11.5 | 100 | 24.2 | 2000 | |
13.2 | 112 | 21.6 | 2240 |
Voltage, length and wattage can be designed by customer requirements.
Application
- Removing moisture from the floor heating, bathroom or balcony such as in home, office, dormitory, nursing home, hotel, resort, etc.